19
 After tightening the screws, pull the wire
VOLJKWO\WRFRQ¿UPZKHWKHULW¶V¿UPRUQRW
 Do not connect two power cables
together to supply power to the air
conditioner.
 'RQRWH[WHQGWKHSRZHUFDEOHFRQGXFWRU
by cutting.
Installation of Outdoor
Electric Wires
Terminal
block
2600~5275W, Heat Pump models
1 Remove the handle on the right side plate of
outdoor unit by loosening the screw.
6450W, Heat Pump models
2 Take off wire cable clamp. Connect and
screw the power connection cable and signal
control wire (for heap pump model only) onto
the terminal block following corresponding
LGHQWL¿FDWLRQQXPEHUVDQGFRORUVRQWKH
terminal blocks of indoor and outdoor units.
3 To prevent water from entering, make a trap
(“U”) in the connection wires (see page 16).
4 Wrap wires that are not connected with
insulating tape so that they do not touch any
electrical or metal parts.
5 )L[WKHSRZHUFRQQHFWLRQZLUHVZLWKZLUH
clamps.
6 Reinstall the handle.
caution
Handle
Handle
yellow-
brown
black
blue
2
N(1)
3
indoor unit connection
green
Handle
yellow-
brown
black
blue
2
N(1)
3
indoor unit connection
green
Handle
Indoor unit connection
yellow-
green
brown
blue black
Handle
Indoor unit connection
yellow-
green
brown
blue black
Vista de pagina 18