The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt
to make repairs due to the possibility of Electrical shock.
Disconnect power cord before servicing.
IMPORTANT
If any green grounding wires are removed during servicing,
they must be returned to their original position position and
properly secured.
CACA
CACA
CA
UTIONUTION
UTIONUTION
UTION
All electrical parts and wiring must be shielded from torch flame.
Do not allow torch to contact insulation; it will char at 200°F
and flash ignite (burn) at 500°F. Excessive heat will distort the
plastic liner.
NONO
NONO
NO
TETE
TETE
TE
This product comes equipped with an Adaptive Defrost
Control (ADC). To initiate Defrost, depress the Fresh Food light
switch 5 times in 6 seconds (light bulb must be working). To
terminate defrost, depress the Fresh Food light switch 5 times
in 6 seconds.
SERSER
SERSER
SER
VICE DVICE D
VICE DVICE D
VICE D
AA
AA
A
TT
TT
T
A SHEETA SHEET
A SHEETA SHEET
A SHEET
241532600
ICE & WATER - AUTOMATIC DEFROST
COUNTER DEPTH SIDE BY SIDE – R134a
ICE MAKER INFORMAICE MAKER INFORMA
ICE MAKER INFORMAICE MAKER INFORMA
ICE MAKER INFORMA
TIONTION
TIONTION
TION
Test Cycling
Remove cover by inserting screwdriver in notch at bottom and prying
cover from housing. Use screwdriver to rotate motor gear
counterclockwise until Holding Switch circuit is completed. All
components of ice maker should function to complete the cycle.
Water Fill Volume
The water fill adjustment screw will change the fill time. One full turn is
equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3
oz.). When a water
valve is replaced,
the fill volume must
be checked.
IMPORIMPOR
IMPORIMPOR
IMPOR
TT
TT
T
ANTANT
ANTANT
ANT
Please return this sheet to it’s original location.
PERFORMANCE DATA
NO LOAD AND NO DOOR OPENINGS AT MID-POINT CONTROL SETTING
Type A with Run/Start Capacitor 85°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 32 TO 40% 55 TO 65%
Freezer Temperature
0° TO 4°F
-18° to -16°C
-1° TO 3°F
-18° to -16°C
Refrigerator Temperature
34° TO 39°F
1° to 4°C
34° TO 39°F
1° to 4°C
Low Side Pressure (cut-in)
5 to 12 psig
34 to 83 kPa
5 to 12 psig
34 to 83 kPa
Low Side Pressure (cut-out)
-2 to 2 psig
-14 to 14 kPa
-2 to 2 psig
-14 to 14 kPa
High Side Pressure (last 1/3 of cycle)
90 to 115 psig
621 to 793 kPa
130 to 155 psig
896 to 1069 kPa
Wattage (last 1/3 of cycle) 120 to 150 130 to 160
Amps (running) 1.0 to 1.4 1.1 to 1.5
Base Voltage 115 vac (127 vac max) 115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat Heater
Cabinet Size
Cut-In Cut-Out Watts Ohms
23’
25°F
-4°C
47°F
8°C
450 30
Electronic Timer – (ADC) Defrost 24 minutes every 6 to 96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts RPM Amps
2.8 950 CW Opposite Shaft .1 Running
ICE MAKER SPECIFICATIONS
Electrical 115 vac (127 vac max)
Thermostat Opens at 48°F (9°C) Closes at 15°F (-9°C)
Heater Wattage 85
ICE MAKER CONNECTOR PLUG CONNECTIONS
Wire Number Wire Color Connects to:
1
Green/Yellow Ground
2
Yellow Water Valve
3
Black Line
4
Light Blue Neutral