9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar 8,9 kW
Gas re‐
placement:
G30/G31 (3B/P) 50/50 mbar 633 g/h
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
Appliance cat‐
egory:
II2H3B/P
Gas connec‐
tion:
R 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Multi Crown 3,9 1,4 146
Semi-rapid 2,0 0,6 96x
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 50/50 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS
FLOW g/h
Multi Crown 3,7 1,4 85 269
Semi-rapid 2,0 0,6 58x 145
Auxiliary 1,0 0,33 43 73
Installation kit to be ordered from
Authorised Service Centre.
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification GK58DKG4O
Type of hob Built-in hob
Number of gas burners 4
www.electrolux.com18