• Replace the damaged mains cable with a
special cable (type H05VV-F or higher).
Speak to your local Service Centre.
ELECTRICAL CONNECTION
• Install the appliance with a socket supply
line. If there is no socket supply line, the
fixed home electrical system must include
an isolating device with at least a 3 mm-
contact separation to enable a simultane-
ous and all-pole cut off from the mains
(according to NIN SEV 1000).
230V 1N ~400V 2N ~
green-yellow
green-yellow
brown
black brown
blue
blue
230V ~
220V... 240V ~
PE
L1
L2
N
PE
L1
N
33
55
1
1
2
2
4
4
ASSEMBLY
min.
50mm
min.
500mm
min.
2mm
electrolux 13