To replace the connection
cable use only H05V2V2-F
T90 or equivalent type. Make
sure that the cable section is
applicable to the voltage load
and the working temperature.
The yellow/green earth wire
(B) must be approximately 2
cm longer than the live and
neutral wire (A).
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase. There must be
no cut or stray strands of wire present.
The cord clamp must be correctly
attached to the outer sheath.
8.8 Building In
min. 600 mm
min. 55 mm
min. 650 mm
560 mm
480 mm
min. 100 mm
30 mm
A) supplied seal
B) supplied brackets
CAUTION!
Install the appliance only on a
worktop with flat surface.
8.9 Possibilities for insertion
The panel installed below the hob must be
easy to remove and let an easy access in
case a technical assistance intervention is
necessary.
Kitchen unit with door
min 20 mm
(max 150 mm)
30 mm
60 mm
B
A
A) Removable panel
B) Space for connections