9.3 Other technical data
TOTAL POWER:
Gas original: G20 (2H) 20 mbar = 9 kW
Gas replacement: G30 (3+) 28-30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
Electric supply: 230 V ~ 50 Hz
3 core flexible cable with non rewireable plug fitted with a 3
amp cartridge fuse
Appliance category: II2H3+
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
1/100 mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
4,0 1,4 98 291 286
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
10. ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol .
Put the packaging in applicable containers
to recycle it. Help protect the environment
and human health and to recycle waste of
electrical and electronic appliances. Do
not dispose appliances marked with the
symbol with the household waste.
Return the product to your local recycling
facility or contact your municipal office.
*
www.electrolux.com16