Electrolux EHG30200K Manual de usuario Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
Electrical connection
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in ac-
cordance with the current regulations.
THIS HOB MUST BE EARTHED.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to the
mains plug after installation.
Do not pull the mains cable to disconnect
the appliance. Always pull the mains
plug.
The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in conform-
ity with the standard and regulations
force.
The power cable must be placed in such
a way that it does not touch any hot part.
Connect the appliance to the mains with
a device that lets to disconnect the appli-
ance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
None of a parts of the connection cable
can not get a temperature 90°C.
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety this should be undertaken
by a qualified electrician, e.g. your local
Electricity Board, or a contractor who is on
the roll of the National Inspection Council
for Electrical Installation Contracting (NICE-
IC).
The manufacturer declines any liability
should these safety measures not be
observed.
This hob is designed to be connected to a
230 V 50 Hz AC electrical supply.
Before switching on, make sure the elec-
tricity supply voltage is the same as that in-
dicated on the hob rating plate. The rating
plate is located on the bottom of the hob.
The hob is supplied with a 3 core flexible
supply cord.
Upon completion there must be no cut, or
stray strands of wire present and the cord
clamp must be secure over the outer
sheath.
Important! A cut off plug inserted into a 13
amp socket is a serious safety (shock)
hazard. Ensure that the cut off plug is
disposed of safely.
Important! The replacement of electric
cable must be carried out exclusively by the
service force centre or by personnel with
similar competencies, in accordance with
the current regulations.
Replacement of the connection cable
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown (or
black) phase wire.
Assembly
40-50 mm
55 mm
30 mm
min. 650 mm
490 mm
min. 100 mm
600 mm
270 mm
If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side bracket
and supplementary seals is available at our
Service Centres. The relevant installation in-
structions are supplied within the kit pack-
age.