electrical installation must have an isola-
tion device which lets you disconnect the
appliance from the power supply. The iso-
lation device must have a contact opening
width of minimum 3 mm (in reference to
NIN SEV 1000). The customer must have
a socket for the electrical connection that
is accessible and outside the coordination
room. The length of the connection cable
must be approximately 120 cm with lines
connected directly to the power supply.
D
E
F
Only a qualified person can con-
nect the appliance to the electrici-
ty supply.
1.
Open the mains terminal cover (D).
2.
Put the connection cable into the
supplied rings (E). This is to prevent
the cable from rubbing against the
drawer. The connection cable is on
the housing side.
3.
Install the cable grip (F).
4.
Connect the terminal as in the illustra-
tion.
5.
Put the cable into the strain relief
clamp.
6.
Close the mains terminal cover.
11.3 Connection diagram 400 V
Phase definitions: L1, L2, L3 (or R, S,T)
WARNING!
If service is required always dis-
connect the appliance from the
power supply.