Problem Possible cause Remedy
Burner cap and crown are
placed incorrectly.
Place the burner cap and
crown correctly.
The flame extinguishes im‐
mediately after ignition.
Thermocouple is not heat‐
ed up sufficiently.
After lightning the flame,
keep the knob pushed for
equal or less than 10 sec‐
onds.
The flame ring is uneven. Burner crown is blocked
with food residues.
Make sure that the injector
is not blocked and the
burner crown is clean.
7.2 If you cannot find a
solution...
If you cannot find a solution to the
problem yourself, contact your dealer or
an Authorised Service Centre. Give the
data from the rating plate. Make sure,
you operated the hob correctly. If not the
servicing by a service technician or
dealer will not be free of charge, also
during the warranty period. The
instructions about the Service Centre
and conditions of guarantee are in the
guarantee booklet.
8. INSTALLATION
WARNING!
Refer to Safety chapters.
8.1 Before the installation
Before you install the hob,
write down the serial number
(Ser. Nr) from the rating
plate. The rating plate is on
the bottom of the hob.
ELECTROLUX
EQG4120BOG
PNC 941 460 008
01
Typ 55 FED 04 GA 220 - 240 V
50 - 60 Hz
Gas type: G20 2H
2E+ - 20 mbar
PIN 0063CL3461
Butan: 350 g/h Qn (Hs): 4.9 kW
Ser.Nr. .................
8.2 Gas Connection
WARNING!
The following instructions
about installation,
connection and maintenance
must be carried out by
qualified personnel in
compliance with standards
and local regulations in
force.
Make sure that during the installation the
appliance is not connected to electrical
supply. Disconnect the mains plug or
deactivate the fuses. Disconnect the
mains gas supply.
Make sure that there is a stop tap
assembles between the gas supply of
house and the appliance.
The settings for this appliance are
located on the rating plate. The present
settings for the type of gas and gas
pressure are on a sticker.
Choose fixed connections or use a
flexible pipe in stainless steel in
ENGLISH 11