8.3 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable
use the following (or higher) mains
cable type: H05V2V2-F T min 90°C.
Speak to your local Service Centre.
8.4 Electrical connection
Install the hob with a socket supply line. If
there is no socket supply line, the fixed
home electrical system must include an
isolating device with at least a 3 mm-
contact separation to enable a
simultaneous and all-pole cut off from the
mains (according to NIN SEV 1000).
400
L1
L2
N
PE
L1
N
PE
8.5 Assembly
min.
50mm
min.
500mm
min.
2mm