Electric supply: 230 V ~ 50 Hz
Appliance category: II2H3+
Gas connection: G 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 4,0 1,4 146
9.5 Gas burners for LPG G30/G31 28-30/37 mbar
BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Triple
Crown
4,0 1,4 98 291 286
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification PQX310UV
Type of hob Built-in hob
Number of gas burners 1
Energy efficiency per
gas burner
(EE gas burner)
Centre middle - Triple Crown 53.0%
Energy efficiency for the
gas hob
(EE gas hob)
53.0%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid.
• If it is possible, use a pressure cooker. Refer to its user manual.
ENGLISH 15