5
Technical specifications
The technical data is indicated in the rating plate on the left side
inside the appliance.
Height 850 mm
Width 495 mm
Depth 600 mm
Installation
Take utmost care when handling your appliance so as not
to cause any damages to the cooling unit with consequent
possible fluid leakages.
¥ During normal operation, the condenser and compressor at the
back of the appliance heat up considerably. Always ensure that
there is adequate ventilation as a failure to do this will result in
component failure and possible food loss. See installation
instructions.
¥
Important: if the supply cord is damaged, it must be replaced by
a special cord or assembly available from the manufacturer or its
service agent.
Positioning
¥ Unpack the cabinet and check that it is in good condition and
free of any transport damage.
¥ Place the refrigerator away from direct sunlight and heat
sources.
¥ Maintain recommended ventilation.
¥ For safety reasons, minimum ventilation must be as shown in the
figure.
Appliance positioned under overhanging kitchen wall units (see
Fig.-A). Appliance positioned without overhanging kitchen units
(see Fig.-B).
Attention: keep ventilation openings clear of obstruction.
¥ Two adjustable feet at the cabinet base allow accurate levelling
of the appliance.
The climate classification can be found on the rating plate, which
is located inside the cabinet on the left hand wall.
The following table shows which ambient temperature is correct
for each climate classification:
Climate
classification
SN +10 to +32¡C
+16 to +32¡C
+18 to +38¡C
+18 to +43¡C
N
ST
T
for an ambient temperature of
Electrical connection
Before plugging in, ensure that the voltage and frequency shown
on the serial number plate correspond to your domestic power
supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized auto-
transformer must be used.
Important
The appliance must be earthed.
The power supply cable plug is provided with a contact for
this purpose.
If the domestic power supply socket is not earthed.
connect the appliance to a separate earth in compliance
with current regulations, consulting a specialist technician.
The Manufacturer declines all responsibility if the
above safety precautions are not observed.
This appliance complies with the following E.E.C. Directives:
- 87/308 EEC of 2/6/87 relative to radio
interference suppression.
- 73/23 EEC of 19.2.73 (Low Voltage Directive) and
subsequent modifications.
- 89/336 EEC of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
Attention!
It must be possible to disconnect the appliance from the
mains power supply; the plug must therefore be easily
accessible after installation.
Door reversal
Proceed as follows:
1. remove screws (A) which secure the worktop (B) on the back;
2. move the top (B) slightly to release it from the retainers and
remove it;
3. Unscrew the top hinge (C) and reÞt it on the opposite side.
4. Refit the worktop (B).
Comentarios a estos manuales