8. TROUBLESHOOTING
CAUTION!
Refer to the chapters on safety.
8.1 What to do if…
Problem Possible cause Solution
The pouch is not
sealed correctly.
The sealing time is not correct. Change the sealing time.
The cover gasket is dirty or
worn.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
The pouch is not placed
correctly on the sealing bar.
Position the pouch correctly.
The sealing bar is worn (the
Teon coating is burnt).
Replace the sealing bar (contact
the Technical Assistance
Service for a replacement).
The blade placed under the
Teon of the sealing bar is
broken.
Replace the blade (contact the
Technical Assistance Service for
a replacement).
Final vacuum is
poor.
The set vacuum level is not
correct.
Change the vacuum level.
The cover gasket is dirty or
worn.
Clean or replace the cover
gasket (contact the Technical
Assistance Service for a
replacement).
The cover is not closed
correctly.
Close the cover correctly.
Make sure that objects or dirt
are not found between the cover
and tank.
The cover does
not open.
No power supply. Wait until the power supply is
restored.
The cover is
cracked or
broken.
Damaged cover. Replace the cover (contact the
Technical Assistance Service for
a replacement).
The and
buttons ash.
“Reconditioning cycle”
in progress.
Wait for the end of the
“reconditioning cycle” (15
minutes).
The vacuum
cycle is stopped
within a few
seconds and
the button
ashes.
The cover gasket is dirty or
worn.
Clean or replace the gasket of
the cover and check that it is
closed properly.