25
N.B. The default parameters (DEF.) may vary for different
appliance models.
D.6 LIST OF USER PARAMETERS
SYMBOL RANGE DEF.
MIN
Internal clock: Minutes 0..59 0
HOUR
Internal clock: Hours 0..23 0
DAY
Internal clock: Days 1..31 1
MON
Internal clock: Month 1..12 1
YEAR
Internal clock: Year 0..99 0
SrF
Indicates the cell temperature set point for the positive holding cycle and the conservation
phase after positive chilling
-
25..10°C/F
3
SFF
Indicates the cell temperature set point for the negative holding cycle and the conservation
phase after negative chilling
-
25..10°C/F
-25
LAC
Temperature difference from absolute temperature/conservation set point, below which a
low temperature alarm is generated
-50..125°C/
F
5
HAC
Temperature difference from absolute temperature/conservation set point, below which a
high temperature alarm is generated
-50..125°C/
F
5
CdiF
Indicates whether the LAC and HAC temperature limits are expressed as differential (d) or
absolute (A).
A/d D
SLd
Indicates duration of sanitation cycle 0..240 10
bCCy
Buzzer mode to indicate to indicate correct conclusion of a chilling cycle Nob bbl
'nob' = buzzer off bbl
'bbl' = buzzer on for 30 seconds lbl
"llb" = buzzer on until any key is pressed
bFCy
Buzzer mode to indicate HACCP alarms bbl
bAll
Buzzer mode to indicate a generic alarm lbl
CCEt
“CUSTOM” standards: END OF POSITIVE CHILLING TEMPERATURE 0..CbSt°C/F 10
CCtI
CUSTOM” standards: END OF POSITIVE CHILLING TIME 0..360 min 110
CFEt
“CUSTOM” standards: END OF NEGATIVE CHILLING TEMPERATURE
-
35..CbSt°C/ -18
CFtI
CUSTOM” standards: END OF NEGATIVE CHILLING TIME 0..360°C/F 270
CbSt
CUSTOM” standards: START OF CHILLING TIME 0..127°C/F 63
EICE
The utility enables the utility of cycles ICE P1 and P2 instead of the custom programmes Y/N N
tPrA
Indicates printing cycle during a chilling cycle. If set to 0, only the temperatures at the
beginning and end of the cycle are printed.
1..255 min 5
tPrC
Indicates the printing interval in conservation /holding. If set to 0, no value is printed. 1..255 min 30
PrnL
Configuration of printout language:
It = Italian, Gb = English, dE = German, fr = French, Es = Spanish, Se = Swedish
It/Gb/dE/fr/
Es/Se
Gb
Adr
Network address 01-FF
1
E485
Type of connection Prn/PC Prn
"Prn" = Printer;
"PC" = Personal Computer;
nOr
Indicates applicable standards, whether NF, “UKorCUSTOM nF, Uk, CuS
t
Uk
REL
Software version --