electrolux Installation 3
Table of characteristics
Check for gas leaks
This check should be carried out immediately after connecting the gas and
each time the appliance is reconnected after being unused for a time.
Once the rubber pipe is connected to the gas supply, carry out the following
operations:
1. Open the gas valve on the LPG bottle (or turn the shut-off
tap if methane supplied).
Do not light the burners yet.
2. With the gas pressure in the pipe, look for any leaks by
brushing a soapy water-based solution onto the gas
unions. A gas leak will cause bubbles to form.
Do not use naked flame to look for leaks.
3. Close the gas valve on the bottle (or the methane shut-off
tap), eliminate the gas leak and repeat the test as
described in points 1 and 2.
BURNERS GRILL
Rated power kW 6.20
Reduced power kW 2.20
CONSUMPTION EGL9000X EGL6000X
G20 20mbar m
3
/h 0,572 0,286
G30 28..30mbar g/h 436,628 218,314
NOZZLE DIAMETER
G30 28..30mbar G31 37mbar n° 127
G30 50mbar G31 50mbar n° 110
G20 20mbar n° 190
G25 25mbar n° 200
G25 20mbar n° 220
BY-PASS DIAMETER
G30 28..30mbar G31 37mbar n° Reg.
G30 50mbar G31 50mbar n° Reg.
G20 20mbar mm Reg.
G25 25mbar mm Reg.
G25 20mbar mm Reg.