Mounting
Minimum distance
to wall:
150 mm
Minimum distance to
wall (non flammable
material): 50 mm
Reinforcement
beams
Caution: In order to avoid a hazard this
appliance must be installed according to
these instructions for installation, also
complying with Gas Safety (installation
& use) Regulation
The hob unit can be mounted in any type
of kitchen with a table surface whose
thickness is between 28 mm and 40 mm.
Headroom
The distance to any shelves or tops of a
cabinet under the hob is to be at least 55
mm.
Fixing
Screw the fixing brackets out to such an
extent that they can be turned in under
the table top. Tighten the brackets on to
the table top with an ordinary
screwdriver.
Cut-out measurements
One rectangular hole is sawn out for the
hob combination chosen.
The depth of the cut-out for any unit is:
490 mm
Length of hole = sum of all units`
externally measured lenght, less 20 mm.
Mounting of Reinforcement
Beams
A reinforcement Beam, with supporting
flanges at each end, is included with each
two-burner unit. For unit combinations, a
reinforcement beam must be used
between each unit.
MIN 55
13
If is not necessary to attach the
reinforcement beam to the table
surface, as it is held in place by a
specially designed moulding, which is
incorporated in the hob unit´s flanges.
The unit´s externally
measured length
145 mm:
Cooker hood
290 mm:
Two-burner standard electric hob
Two-burner ceramic-top electric hob
Two-burner gas hob
Grill
Wok
580 mm:
Four-burner ceramic-top electric hob
Four-burner gas hob
Installation of a single unit
When mounting a single unit, be it a
half or full size unit, in a table top
which is thicker than 30 mm, it is
necessary to make a special notch in
both sides of the cut-out hole, as
shown in the adjacent drawing.
The purpose of these notches is to
create space for the electrical cables.