electrolux integrated bbq 600/300mm universal LPG installation 11
Preparing the unit for Universal LPG installation
This barbecue is supplied set up for Natural Gas and is
labelled accordingly. A Universal LPG conversion kit is
available from Electrolux Spare Parts to enable conversion
to Universal LPG and connection to a 9kg bottle.
Remote ULPG supply
The barbecue can be plumbed into a remote or
household ULPG supply. Never connect the barbecue
to an unregulated supply, ensure supply pressure at the
barbecue is 2.75kPa. Electrolux strongly recommends that
a manual shut off valve be installed in the gas supply line in
an accessible position so that gas can be turned off in the
event of an emergency, or during servicing.
NOTE:
Conversion of this unit to Universal LPG must be carried
out by a qualified licensed person and a Certificate of
Compliance must be issued to the owner on completion
of the installation and conversion. The components are:
For models EQBH60AS & EQBL60AS
Hose and regulator assembly
Small plastic bag containing 4 brass injectors (0.90mm)
1 Universal LPG sticker
1 brass adaptor
1 sealing washer
For models EQBL30AS
Hose and regulator assembly
Small plastic bag containing 1 brass injector (0.90mm)
1 Universal LPG sticker
1. Change the injectors
Remove the front cover.
Remove the burner retaining clips as shown.
remove spring clip
by rotating over
burner tube end
front cover
Unscrew and replace the injector nipples located in the
end of each tube feeding the burners. The Universal LPG
injectors have a 0.90mm diameter orifice in them. They
appear substantially smaller than the Natural Gas injectors.
LPG injector
Re-fasten the clip to retain the tube in the burner.
Do not over tighten or distort supply tube.
Fit the front cover back on and fasten screws.
2. Adjust the turndown setting on the valve
Remove the knobs from the valves.
Remove rubber grommets from control panel holes.
For each valve rotate the valve rotation limiting screw
anti-clockwise using a Philips head screw driver until
valve shaft is able to be rotated more than 180°
(approx 3 turns).
Valve rotation
limiting screw
Re-t grommets and knobs
3. For EQBH60AS & EQBL60AS only, connect the adaptor
to the barbecue gas inlet. Ensure the blue sealing
washer is in place. Do not over tighten.
4. Connect the hose. Do not over tighten.
5. Following connection to gas bottle, conduct a leak test
for all joints made (refer leak test procedure page 12).
6. Light all burners and one at a time set the burner to the
lowest setting and check a small steady flame is achieved.
EQBH60AS & EQBL60AS
barbecue gas inlet
sealing washer
brass adaptor
LPG hose and
regulator assembly
EQBL30AS
LPG hose and regulator assembly
gas inlet
7. Replace the ‘gas type’ sticker
Locate the ‘Natural Gas’ sticker located on or near the gas
inlet and remove it. Put the Universal LPG sticker in its place.
Universal LPG installation
INTBBQ600/300_Jun11.indd 11 30/06/11 11:52 AM