Cleaning the strainer insert
If the water flowrate is reduced by dirt from the cold water line, the strainer-
insert should be cleaned as follows:
Flow rate limiter
The flow rate limiter (2) is installed in the cold
water connector (1) to allow a constant outlet
temperature at high flow pressures of approx. 40° C,
suitable for showering.
(See table page 4 and 6)
Shut off cold water on shutoff unit (1)
Loosen cap nut (2 ) using a spanner
Take out and clean strainer (3)
Re-assemble in reverse sequence
Open cold water on shutoff unit (1); check
tightness
2
1
3
1
2