10 www.electrolux.com
9.2 Preparation
Installation Location
Do not install the unit in a place with
much oil, steam, sulde gas. Otherwise,
the product may deform and fail.
Preparation before installation
1. Check whether the following assem-
blies are complete.
No. Name Qty. Remarks
1
Wire controller 1
2
Wood Mounting Screw 3
GB950-86 M4X20(For Mounting on
the Wall)
3
Mounting Screw 3
GB823-88 M4X25(For Mounting on
the
Electrical Switch Box)
4
Installation Manual 1
5
Owner’s Manual 1
6
5-terminal Group 1 RS9005E
7
Terminal Installation Screw 2 ST3.9x12-F-H GB845-85
2. Prepare the following assemblies
on the site.
No. Name Qty. Type Remarks
1
5-core shielded cable 1
RVVP-
0.5mm2x5
The longest wire is 15m
2
Switch box 3
3
Wiring Tube(Insulating
Sleeve and Tightening
Screw)
3
Note to installation of wire controller:
1. This manual contains information
about the procedure of installing wire
controller. Please refer to Indoor Unit
Installation Manual for connecting
between Wire Controller and Indoor
Unit.
2. Install the Wire joint,5p to the
appointed position of the electric
controlling Box.
3. Circuit of Wire Controller is low volt-
age circuit, Never connect it with a
standard 220V/380V circuit or put
it into a same Wiring Tube with the
circuit, and the interval must be more
than 300~500mm.
4. The shield cable must be connected
stable to the ground, or transmission
may fail.
5. Do not to attempt to extend the shield
cable by cutting, if it is necessary,
use Terminal Connection Block to
connect.
6. After nishing connection, do not use
Megger to have the installation check
to the signal wire.