Important safety requirements
This hob must be installed in accordance with the IEE Wiring Regulations
(Current Edition).
Detailed recommendations are contained in the following British Standards Codes
Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.
Location
This hob has been registered as a "Class X" appliance according to Fire Risk
Regulations. Minimum distances detailed below must be observed.
The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but
not in a bathroom or shower room.
Ensure that there is a minimum distance
of 55 mm between the rear cut out edge
and the wall.
A minimum distance of 100 mm must
be left between the side edges of the
cut out and any adjacent cabinets or
walls.
The minimum distance combustible
material can be fitted above the hob in
line with the edges of the hob is 400 mm.
If it is fitted below 400 mm a space of
50 mm must be allowed from the edges
of the hob.
The minimum distance combustible
material or a cooker hood can be fitted
above the hob is 650 mm.