Electrolux EHGC93CI Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
13electrolux gas cooktops testingtheappliance
Afterinstallation,testtheapplianceandensurethatit
operatescorrectlybeforehandingitovertothecustomer.
Thefollowingprocedureisrecommended:
1. Turnonthegasandelectricitysupplyandattempt
ignitiononallburners,bothseparatelyandin
combination.(Forcorrectprocedurerefertopage3
LightingBurners).Notethatadditionaltimeneedsto
beallowedfortheinitiallightingasairhastobepurged
fromthepipes.
2. Observetheflameappearanceoneachburner
(Figure11).Ifitismuchlargerormuchsmallerthan
expected,theinjectorsizeandsupplypressurerequire
checking.Whereaflameisunsatisfactory,refertothe
TroubleshootingGuide(page5)tocorrectthefault.If
theTroubleshootingGuidedoesnotsolvetheproblem,
calltheServiceCentre.
3. Whenalltheforegoingissatisfactory,checkthe
turndown(minimumorlow)settingoneachburner,
asthismayneedadjustment.Valveshaveabypass
controllingscrew,whichmaybeaccessedbyremoving
theknob.Thisscrewwillbelocatedonaparticulararea
ofthevalve(referFigure12).Normally,thiswillhave
beencorrectlysetatthefactoryforuseonNaturalGas
(NG)andshouldnotrequireadjustment.
tips and information
IftheappliancehasbeenconvertedtoLPG,thenthe
bypassscrewwillHAVE tobescrewedinuntilasmall,
stableflameresults.
Please ensure the supply pressure has been
checked PRIOR to any adjustment.
4. Iftheappliancecannotbeadjustedtoperformsafely
informthecustomeroftheproblemandaffixan
appropriatewarningnoticetotheappliance.Ifthefault
appearstobedangeroustheapplianceshouldbe
disconnected.Ifaminorfaultexists,thecustomermay
wishtousetheappliancewhileawaitingservice.
Ifafaultcannotbefixed,pleasecalltheServiceCentre.
5. Thecustomershouldbeadvisedthat,intheevent
ofafault,thelocalserviceorganisationortheretailer
fromwhomtheappliancewaspurchasedshouldbe
contacted.
6. Whensatisfiedthattheunitisoperatingcorrectly,turn
offandinstructthecustomeroncorrectoperationas
outlinedinthisbooklet.Askthecustomertooperate
thecontrolstoensurethatthecorrectprocedureis
understood.
Testingapplianceoperation
Flamesizeadjustedtomaximum
Flamesizeadjustedtominimum
Bypassscrew
Figure11
Figure12
caution
Servicing must only be carried out by an authorised
service person.
Injectorsizesrequiredforvariousgastypesareshownin
Table3(page10).Theappliancetestpointpressurefor
eachgastypeisalsoshown.
Formodelidentificationafterinstallation,anadditionaldata
platestickerhasbeenprovided.Thisstickeristobestuck
ontoadjacentcabinetry.
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18

Comentarios a estos manuales

Sin comentarios