Vista de pagina 15
9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Triple Crown 56
9.3 Other technical data
TOTAL POW‐
ER:
Gas original: G20 (2H) 20 mbar 3,8 kW
Gas replace‐
ment:
G30/G31 (3B/P) 30/30 mbar 276 g/h
Electric sup‐
ply:
220-240 V ~ 50/60 Hz
Appliance cat‐
egory:
II2H3B/P
Gas connec‐
tion:
G 1/2"
Appliance
class:
3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Triple Crown 3,8 1,4 146
9.5 Gas burners for LPG G30/G31 30/30 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Triple Crown 3,8 1,4 98 276
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGC3313NVK
Type of hob Built-in hob
Number of gas burners 1
Energy efficiency per gas burner
(EE gas burner)
Centre middle - Triple Crown 54.1%