9.2 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Rapid 52
Semi-rapid 35
Auxiliary 32
9.3 Other technical data
TOTAL POWER: Gas original: G20 (2H) 20 mbar = 7,9 kW
Electric supply: 220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3
amp cartridge fuse
Appliance category: I2H
Gas connection: R 1/2"
Appliance class: 3
9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
Rapid 2,9 1,2 120B
Semi-rapid 2,0 0,75 102
Auxiliary 1,0 0,5 73F
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification EGT6647LOK
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left middle - Rapid 62.7%
Centre rear - Semi-rapid 60.5%
Right middle - Semi-rapid 59.3%
Centre front - Auxiliary not applicable
Energy efficiency for the gas hob
(EE gas hob)
60.8%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
www.electrolux.com18