must fit an applicable pressure adjuster on
the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burner:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-
pass screw position. If you change from
natural gas 20 mbar to liquid gas, fully
tighten the adjustment screw in. If you
change from liquid gas to natural gas 20
mbar, undo the by-pass screw approxi-
mately 1/4 of a turn for screw 2, 1/3 of a
turn for screw 1.
1
2
1 Minimum adjustment screw for dual
burner both crowns
2 Minimum adjustment screw for dual
burner internal crown
5. Make sure the flame does not go out
when you quickly turn the knob from the
maximum position to the minimum posi-
tion.
Electrical connection
Any electrical work required to install this
hob should be carried out by a qualified
electrician or competent person, in ac-
cordance with the current regulations.
THIS HOB MUST BE EARTHED.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to the
mains plug after installation.
Do not pull the mains cable to disconnect
the appliance. Always pull the mains
plug.
The appliance must not be connected
with an extension cable, an adapter or a
multiple connection (risk of fire). Check
that the ground connection is in conform-
ity with the standard and regulations
force.
The power cable must be placed in such
a way that it does not touch any hot part.
Connect the appliance to the mains with
a device that lets to disconnect the appli-
ance from the mains at all poles with a
contact opening width of minimum 3
mm, eg. automatic line protecting cut-
out, earth leakage trips or fuse.
None of a parts of the connection cable
can not get a temperature 90°C.
Electrical Requirements
Any permanent electrical installation must
comply with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety this should be undertaken
by a qualified electrician, e.g. your local
Electricity Board, or a contractor who is on
the roll of the National Inspection Council
for Electrical Installation Contracting (NICE-
IC).
The manufacturer declines any liability
should these safety measures not be
observed.
This hob is designed to be connected to a
230 V 50 Hz AC electrical supply.
Before switching on, make sure the elec-
tricity supply voltage is the same as that in-
dicated on the hob rating plate. The rating
plate is located on the bottom of the hob.
The hob is supplied with a 3 core flexible
supply cord incorporating a 3 amp plug fit-
ted. In the event of having to change the
fuse, a 3 amp ASTA approved (BS 1362)
fuse must be used.
6 electrolux