3. Using a socket spanner 7 unscrew and
remove the nozzles replacing them with
the ones required for the kind of gas in
use (see table " Burner characteristics " ).
4. Reassemble the parts following the same
procedure backwards.
5. Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
These burners do not need any primary air
regulation.
Adjustment of minimum level
To adjust the minimum level of the burners,
proceed as follows:
1. light the burner;
2. turn the knob on the position of minimum
flame;
3. remove the knob;
4. with a thin screwdriver, adjust the bypass
screw;
If changing from natural gas 20 mbar/13
mbar to liquid gas, completely tighten
the adjustment screw in, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
20 mbar, undo the by-pass screw about
1/4 of a turn, until a small regular flame
is obtained.
If changing from natural gas 20 mbar to
natural gas 13 mbar undo the by-pass
screw about 1/4 of a turn, until a small
regular flame is obtained.
If changing from liquid gas to natural gas
13 mbar, undo the by-pass screw about
3/4 of a turn, until a small regular flame
is obtained.
Reassemble the parts following the same
procedure backwards.
Finally, check the flame does not go out
when quickly turning the knob from the max-
imum position to the minimum position.
Electrical connection
The unit is preset to work with a voltage of
single phase 230 V.
Before making the connection make sure
that:
• the energy power available in the user's
house is sufficient for the normal supply of
this appliance (see rating plate)
• the unit is correctly connected to earth
through a suitable plug and according to
the installation country Laws
• the socket or the omnipolar switch used
for the connection must be easilv reached
with the installed appliance
The appliance is supplied with electric cable,
therefore you will have to fit it with a standard
plug, suitable for the total electric load shown
on the rating plate. The plug is to be inserted
into a suitable wall socket.
If you wish to directly connect to the mains,
you have to interpose an omnipolar switch
with a minimum opening between contacts
of 3 mm, between the unit and the mains,
complying with the existing regulations.
The brown live wire (originating from the
clamp of the appliance junction box) must al-
ways be connected to the phase of the mains
supply. In any case, the supply cord must be
positioned in such a way as it does not reach
in any point a temperature higher by 50
°
C
than the room temperature.
Replacement of the electric cable
Warning! The replacement of electric
cable must be carried out exclusively by
the service force centre or by personnel
with similar competencies, in
accordance with the current regulations.