9.4 Gas burners for NATURAL GAS G20 20 mbar
BURNER NORMAL POWER
kW
MINIMUM POWER
kW
INJECTOR MARK
1/100 mm
Rapid 2,2 0,95
Semi-rapid 1,65 0,55
9.5 Gas burners for LPG G30/G31 50/50 mbar
BURNER NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK 1/100
mm
NOMINAL GAS
FLOW g/h
Rapid 2,1 0,95 153
Semi-rapid 1,6 0,55 116
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification GK58DKG4O
Type of hob Built-in hob
Number of gas burners
Energy efficiency for the gas hob
(EE gas hob)
59.9%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
• Before use, make sure that the burners and pan supports are assembled correctly.
• Use cookware with diameters applicable to the size of burners.
• Center the pot on the burner.
• When you heat up water, use only the amount you need.
• If it is possible, always put the lids on the cookware.
• When the liquid starts to boil, turn down the flame to barely simmer the liquid.