Vista de pagina 17
and work surfaces that align to the
standards.
During installation in combustible matter,
NIN SEV 1000 and fire protection
guidelines and regulations of the
Association of Cantonal Fire Insurance
shall be strictly adhered to.
8.3 Connection cable
The hob is supplied with a connection
cable.
To replace the damaged mains cable
use the following (or higher) mains
cable type: H05V2V2-F T min 90°C.
Speak to your local Service Centre.
8.4 Electrical connection
Install the hob with a socket supply line. If
there is no socket supply line, the fixed
home electrical system must include an
isolating device with at least a 3 mm-
contact separation to enable a
simultaneous and all-pole cut off from the
mains (according to NIN SEV 1000).
400
L1
L2
N
PE
L1
N
PE
8.5 Assembly
min.
50mm
min.
500mm
min.
2mm