3. Technical
characteristics
Noise level
Airborne noise emitted by the machine (values established as from measurements made on
the machine at points A,B,C,D).
Ironing width 1 m 1.4 m 1.6 m
Weighted acoustic pressure
level (A) in dB(A)
Point A 52 54 54
Point B 57 57 57
Point C 52 52 52
Point D 59 59 59
This ironing machine should only be used for previously washed and pre-dried,
machine-ironable textiles.
In this normal case of use, it is not necessary to connect the exhaust duct to the
open air.
In the opposite case, the exhaust duct must be connected to the open air, by the shortest
way, and with as few bents as possible.
Incline the fl exi-hose downwards, as compared to the machine.
Protect the end of the exhaust duct from the bad weather.
Do not connect the exhaust duct to a gas, coal, fuel oil furnaces chimney. Separate it also
from any other ducting (tumble dryer, fi nishing cabinet...).