2. Release the screw C, which keep the
burner in position.
3. Carefully move the burner off the
injector support D.
4. Slowly move it to the left side. Make
sure that the burner bush stays on
the burner mouthpiece. Do not apply
force to the wire of the spark plug
connector F and to the thermocouple
conductor E.
5. Release the burner injector D with a
7 mm socket spanner and replace it
with a different one.
Assemble the burner in a revers
sequence.
Replace the gas type sticker near the
gas supply ramp with the one related to
the new gas type.
14.14 Adjusting the minimum
gas level on the oven burner
1. Disconnect the appliance from the
electricity.
2. Remove the knob for the oven
functions. If there is no access to the
bypass screw dismount the control
panel before adjustment start.
3. With a thin and flat screwdriver adjust
the bypass screw A.
The model determines the position of
the bypass screw A.
Changing from natural gas to
liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
3. Connect the appliance to the
electricity.
ENGLISH 29
Comentarios a estos manuales