14.4 Bypass diameters
BURNER Ø BYPASS 1/100 mm
Auxiliary 26 / 25
Semi-rapid 28 / 29
Rapid 38 / 35
Dual 49
Oven 48
Grill 55
14.5 Gas burners for LPG G30 50 mbar
BURNER NORMAL
POWER kW
GAS RATE g/h REDUCED POW‐
ER kW
INJECTOR
MARK 1/100
mm
Dual 5.0 363.6 1.5 40
66
66
Rapid 3.0 218.1 0.72 77
Semi-rapid 2.0 145.4 0.43 60
Auxiliary 1.0 72.7 0.35 43
Oven 3.9 283.6 1.5 87
Grill 2.5 181.8 1.6 68
14.6 Gas connection
WARNING!
Use this appliance with the
LPG supply at a pressure of
50 mbar. If you supply the
appliance with a lower
pressure, the performance of
the appliance will be not
satisfactory.
The gas pipe in the appliance has two
endings. You can connect the gas supply
to either one of them. The pipe that is not
used must be clogged with the pipe
closer, which added to the appliance.
Use a fixed connections or use a flexible
stainless steel pipes in compliance with
the regulation in force. If you use flexible
metallic pipes, make sure they do not
come in touch with mobile parts and they
are not squeezed.
14.7 Flexible nonmetal pipes
connection
If you have an easy access to the
connection, you can use a flexible pipe.
The flexible pipe must be tightly attached
by clamps.