48
TYPE BURNER INJECTORS NORMAL REDUCED NORMAL FEEDING
OF GAS POWER POWER POWER PRESSURE
1/100 mm kW kW m bar
m
3
/h g/h
Big-Rapid 145 4,0 1,2 0,381 -
Semi-rapid 96 2,0 0,45 0,190 - 20
Auxiliary 70 1,0 0,33 0,095 -
Fish kettle burner 119 3,0 0,85 0,286 -
Oven burner 116 3,0 1,0 0,286 -
Grill Burner 111 2,5 - 0,238 -
Big-Rapid 95 3,8 1,2 - 274
Semi-rapid 71 2,0 0,45 - 144
Auxiliary 50 1,0 0,33 - 72
Fish kettle burner 88 3,2 0,85 - 230 28-30/37
Oven burner 82 3,0 1,0 - 216
Grill burner 74 2,3 - - 166
NATURAL
GAS
(Methane)
SPECIFICATIONS OF BURNERS AND INJECTORS
WARNING
If the pressure of gas used is different (or variable) from that foreseen , an appropriate pressure regulator must be installed
on the entry tube.
in case of pressure regulators for GPL are used, these must conform to regulation.
Table 2
LIQUID
GAS
(But./
Prop.)
ADJUSTMENT OF THERMOSTAT
BY-PASS PIN
To reach the thermostat by-pass pin, act as follows:
- take out the knobs;
- remove the front panel;
- adjust the by-pass pin with a thin screwdriver, as
shown in Fig.38;
- finally check that turning quickly the tap from
maximum position to minimum position, the flame
does not go out;
- reassemble the front panel and the knobs.
FO 1061
Fig. 38