electrolux integrated bbq 600/300mm gas specifications 9
model EQBH60AS &
EQBL60AS
EQBL30AS
Gas type Natural
gas
Universal
LPG
Natural
gas
Universal
LPG
Maximum gas
consumption
46 MJ/h 46 MJ/h 11.5 MJ/h 11.5 MJ/h
Injector orifice
diameter (mm)
1.50 0.90 1.50 0.90
Number of
injectors
4 4 1 1
Regulator
pressure
1.00kPa* 2.75kPa 1.00kPa* 2.75kPa
NOTE:
• This appliance MUST be installed and serviced by
a qualified licensed person only.
• This product is intended for outdoor use only.
• This product must be installed as per instructions
which requires the installation of venting to enable
the barbecue to operate correctly. Failure to provide
adequate ventillation for supply of air to the appliance
may result in poor burner performance or excessive
heat build-up within the mounting enclosure.
• Ventillation holes in the unit must not be obscured
by installation.
* The outlet pressure at the natural gas regulator will be
lower with all burners operating. Burner pressure should
read 1.0kPa with one burner operating and approximately
0.90kPa with four burners operating.
For conversion to Universal LPG a conversion kit will need
to be purchased from Electrolux Spare Parts.
EQBH60AS & EQBL60AS
EQBL30AS
Gas Specifications Gas connection detail
INTBBQ600/300_Jun11.indd 9 30/06/11 11:52 AM