31
E 14
25 W - 230 V~
T300°C
A
GB
Always isolate the cooker from the electricity supply, shut off the gas
supply temporarily and proceed as follows.
- change the injectors,
- adjust the minimum flow of the burners.
REPLACEMENT OF COOKTOP INJECTORS
To change the cooktop injectors, proceed as follows: remove the
grids, remove burners and flame-spreaders (see fig.A), change the
injector (see fig.B) and replace it with another one suitable for the new
type of gas (see table D). Re-assemble everything in reverse order,
ensuring you position the flame-spreader correctly.
Fig. 11
MINIMUM FLOW ADJUSTMENT FOR COOKTOP TAPS
To adjust the minimum, proceed as follows: switch the burner on, and
turn the knob towards the minimum flow position . Remove the knob
from the tap, introduce a small screwdriver in to the tap rod (fig. 11).
Attention: in taps with security valve, the minimum adjustment screw
Z is placed outside the tap rod (fig. 12).
WARNINGS
Isolate the cooker from the electricity supply before attempting to
replace the oven lamp.
The oven lamp is of a special type designed to withstand high
temperatures. To replace it, proceed as follows: remove the protective
glass (A) and replace the burnt-out bulb with one of the same type.
Re-fit the protective glass.
DISMANTLING THE COOKTOP
If it becomes necessary to repair or replace internal components,
proceed as follows: remove the glass lid from its position by sliding
off upwards.
Remove the grids, the burners and flame-spreaders (see fig. 13),
unscrew the visible screws V located on the cooktop (see fig. 14).
Dismantle the cooktop by unscrewing the 4 rear screws A (see fig.
15 ).
Loosen the adjustment screw in order to increase the flow or tighten
it to decrease the flow.
The proper adjustment is obtained when the flame is approximately
3 or 4 mm in length.
For butane/propane gas, the adjustment screw must be fully screwed
down.
Make sure that the flame does not go out when passing quickly from
the max. flow to the minimum flow .
Assemble the knob again.
Fig. 12
Z
Values referred to Hs - 15°C - 1013,25mbar
TAB. D
Cat. II 2H3+
TABELLA GENERALE INIETTORI
Kind of gas
mbar
Nozzle
Burners
Power
KW Consum
N° max. min. max. min.
128
Rapide
3,00 0,75 286 l/h 72 l/h reg.
NATURAL 20 101
Semi rapide
1,75 0,48 167 l/h 46 l/h reg.
G 20 77
Auxiliary
1,00 0,33 95 l/h 31 l/h reg.
141
Triple crown
3,80 1,50 363 l/h 143 l/h reg.
BUTANE 28-30 87
Rapide
3,00 0,75 219 g/h 55 g/h 42
G 30 66
Semi rapide
1,75 0,48 128 g/h 35 g/h 31
50
Auxiliary
1,00 0,33 73 g/h 24 g/h 27
PROPANE 37 96
Triple crown
3,80 1,50 109 g/h 95 g/h 60
G 31
N°
By pass
C =
injector
Triple crown
GAS ADJUSTMENT
APPLIANCE MAINTENANCE
Fig.14
Fig. 13
V
TO RAISE AND TO
PUSH IN AHEAD
Fig. 15
A
A
C
C
A
B