14
Burner characteristics
Burner
Normal
power
(MJ/h)
Simmer
power
(MJ/h)
By-
pass
(mm)
Gas Type
Pressure
(kPa)
Nozzle
diameter
(mm)
RAPID
10,5
10,5
2,62
2,62
0,42
Natural Gas
U-LPG
1,00
2,60
1,39
0,90
SEMI-
RAPID
7,0
6,5
1,75
1,62
0,35
Natural Gas
U-LPG
1,00
2,60
1,11
0,71
AUXILIARY
4,2
4,0
1,05
1,00
0,29
Natural Gas
U-LPG
1,00
2,60
0,89
0,55
Before any modifications or
conversion to a kind of different
gas, you must DISCONNECT the
cooker from the electricity supply
and ensure that all control knobs
are in the OFF position, and the
appliance has cooled completely.
Replace the nozzles of the hob
burners
Hob burners
Remove the pan supports;
Remove the caps and the burner
crowns;
Using a No 7 socket spanner
unscrew the nozzles and replace
them with those required for the
type of gas in use (see burners
characteristics table above).
Reassemble the parts following the
same procedure in reverse.
These burners do not need any
primary air regulation.