Electrolux CKG5060W Manual de usuario Pagina 15

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 40
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 14
15
Adjustment of minimum level for
the hob burners
The burner is correctly adjusted
when the flame is stable silent and
goes out without any noise.
When changing the type of gas
check that the minimum level is
correct. The air admission is correct
when the flame is about 4 mm in
length.
The top burners do not need
adjustment of primary air.
Check that, turning the knob quickly
from the maximum position to the
minimum one, the flame does not go
out.
Hob burners
To adjust the minimum level:
Light the burner
Turn the knob to the position of
the minimum flame;
Remove the knob;
Unscrew or screw the by-pass
screw until a regular small flame
is reached.
For U-LPG screw completely the
by-pass screw.
Reassemble the parts following the
same procedure in reverse.
Check that, when turning the knob
quickly from the maximum position to
the minimum one, the flame does not
go out.
no air
correct
adjustment
excess of
air
Vista de pagina 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 ... 39 40

Comentarios a estos manuales

Sin comentarios