electrolux 29
Electrical connection
The unit is preset to work with a voltage
of single phase 230 V.
Before making the connection make sure
that:
- the energy power available in the user's
house is sufficient for the normal supply
of this appliance (see rating plate).
- the unit is correctly connected to earth
through a suitable plug and according to
the installation country Laws.
- the socket or the omnipolar switch used
for the connection must be easilv
reached with the installed appliance.
The appliance is supplied with electric
cable, therefore you will have to fit it with a
standard plug, suitable for the total electric
load shown on the rating plate. The plug is
to be inserted into a suitable wall socket.
If you wish to directly connect to the
mains, you have to interpose an omnipolar
switch with a minimum opening between
contacts of 3 mm, between the unit and the
mains, complying with the existing
regulations. The brown live wire (originating
from the clamp of the appliance junction box)
must always be connected to the phase of
the mains supply. In any case, the supply
cord must be positioned in such a way as it
doesn't reach in any point a temperature
higher by 50°C than the room temperature.
Replacement of the electric cable
Should the supply cord need to be
replaced, use only the following cable types:
H07 RN-F, H05 RN-F, H05 RR-F, H05 VV-
F, H05 V2V2-F (T90), H05 BB-F. It is
necessary that the yellow/green earth wire is
about 2 cm longer than the live and neutral
ones (Fig. 18). After the connection, test the
heating elements for about 3 minutes to
ensure that they are working correctly.
The manufacturer refuses any
responsability in cases where normal
safety measures are not observed.
Fig. 18
Ground (yellow - green)
Neutral
wire
Phase