5.
Replace the rating label (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this label in the package of the injec-
tors supplied with the appliance.
8.3 Adjustment of minimum level
To adjust the minimum level of the
burners:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
A
A)
The by-pass screw
If you change from natural gas 20 mbar
to liquid gas, fully tighten the adjust-
ment screw in.
If you change from liquid gas to natural
gas 20 mbar, undo the by-pass screw
approximately 1/4 of a turn.
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
8.4 Electrical connection
Ground the appliance according to
safety precautions.
Make sure that the rated voltage and
type of power on the rating plate agree
with the voltage and the power of the
local power supply.
This appliance is supplied with a mains
cable.
Any electrical component must be in-
stalled or replaced by the Service Force
Centre technician or qualified service
personnel.
Always use a correctly installed shock-
proof socket.
Make sure that there is an access to
the mains plug after installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
The appliance must not be connected
with an extansion cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is in
conformity with the standard and regu-
lations force.
The power cable must be placed in
such a way that it does not touch any
hot part.
Connect the appliance to the mains
with a device that lets to disconnect the
appliance from the mains at all poles
with a contact opening width of mini-
mum 3 mm, eg. automatic line protect-
ing cut-out, earth leakage trips or fuse.
None of a parts of the connection cable
can not get a temperature 90°C.
8.5 Replacement of the
connection cable
In order to replace the connection cable
speak your local Service Force Centre!
To replace the connection cable use only
H05BB-F Tmax 90°C (or higher) type.
Make sure that the cable section is appli-
cable to the power and the working tem-
perature. The yellow/green earth wire
must be approximately 2 cm longer than
all phase wires.