7. TROUBLESHOOTING
Problem Possible cause Remedy
There is no spark when
lighting the gas
• There is no electrical
supply
• Make sure that the unit
is connected and the
electrical supply is
switched on.
• Control the fuse. If the
fuse is released more
than one time, refer to
a qualified electrician.
• Burner cap and crown
are placed uneven
• Make sure that the
burner cap and crown
are in correct positions.
The flame is blow out im-
mediately after ignition
• Thermocouple is not
heated sufficient
• After lightning the
flame, keep the knob
pushed for approxi-
mately 5 seconds.
The gas ring burns un-
evenly
• Burner crown is
blocked with food resi-
dues
• Make sure that the in-
jector is not blocked
and the burner crown
is clear of food parti-
cles.
If there is a fault, first try to find a solution
to the problem yourself. If you cannot find
a solution to the problem yourself, speak
your dealer or the local Service Force
Centre.
If you operated the appliance in-
correctly, or the installation was
not carried out by a registered en-
gineer, the visit from the customer
service technician or dealer may
not take place free of charge,
even during the warranty period.
8. INSTALLATION
Before the installation
Before the installation of the appliance, re-
cord the information below from the rating
plate. The rating plate is on the bottom of
the appliance casing.
• Model ...........................
• PNC .............................
• Serial number ....................
WARNING!
The following instructions about
installation, connection and main-
tenance must be carried out by
qualified personnel in compliance
with standards and local regula-
tions in force.
8.1 Gas Connection
Make sure that during the installation the
appliance is not connected to electrical
supply. Disconnect the mains plug or de-
activate the fuses. Disconnect the mains
gas supply.