5.5. NTC sensors failure
When there is a failure in NTC sensors, during normal mode the three leds (b),(c) and (d) blink.
The compressor cycle is controlled according to the following way:
sensor failure working time compressor
cycles
defrost time
First start 6 hours controlled by
Air NTC
22 minutes Evaporator NTC
sensor
(no adaptivity)
During working latest time before
failure
controlled by
Air NTC
22 minutes
First start controlled by evap.
NTC
10 min pause
15 min run
controlled by evap.
NTC
Air NTC sensor
(adattivita’)
During working controlled by evap.
NTC
latest times before
failure
22 minutes
First start 6 hours 10 min pause
15 min run
22 minutes Evaporator NTC
sensor + Air NTC
sensor
(no adaptivity)
During working latest time before
failure
latest times before
failure
22 minutes