Defrosting heater:
Power at 230V W 250
Drainage duct heater:
Power at 230V W 43.5
Safety overheating switches:
aperture °C 55
closure °C 45
Settings for refrigerator compartment:
Position of
thermostat knob
Cut-in Cut-out
stand by* Flap closed Flap closed
3 +10 °C +7°C
5 +7°C +4°C
7 +4°C +1°C
* in this position, the thermostat completely blocks the passage of cold air coming from the freezer
compartment.
Settings for freezer compartment:
Position of
thermostat knob
Cut-in Cut-out Alarm
0 -15 °C -16°C -12°C
3 -18 °C -19°C -12°C
5 -21°C -22°C -12°C
7 -23°C -24°C -12°C
Normal operating times:
pre-determined** hrs 6
minimum hrs 4
maximum hrs 25
** A six-hour operating cycle is performed each time the appliance is switched on.
Defrosting:
standard time minutes 22
maximum time minutes 30
temp. for end of defrosting °C +15