6.3. Separate activation of loads
The various buttons can be used to activate and disactivate the compressor, fans and heating elements
separately. The corresponding LED remains lit to indicate the load which has been activated.
If the loads are not disactivated manually, the following safety procedure is performed:
1. the compressor and the fans will switch off automatically after 4 minutes
2. the heating elements will switch off when the temperature reaches +15°C (end of defrosting cycle)
3. above +15°C heating elements disactivate after 4 min.
NOTE: the activation of heating elements allows a manual defrosting.
A= compressor ON/OFF; B= fans ON/OFF; C= heating elements ON/OFF.
6.4. Checking the door switches
The switch on the door of the refrigerator compartment can be checked by noting whether the refrigerator
light switches on.
To check for correct operation of the freezer compartment switch, it is sufficient to check whether the flashing
frequency of the thermostat knob surrounds changes.
6.5. Disactivation of service mode
To exit service mode, press the ON/OFF button (e) for 2 seconds; the appliance returns to normal operation.
If the ON/OFF button is not used, the appliance will return to normal operation automatically after 30
minutes.
6.6 Days counter
The “days counter” function counts the days since the first switching ON of the appliance and it is important
to follow the buttons sequence, without skipping anyone.
To activate this function the ON/OFF button must be pressed during the 5 seconds following the activation of
service mode. The first sounding (long beeps) of the buzzer counts the thousands of day. At the end of the
count during next 10 seconds, after pressing the “rapid freezing” button the buzzer counts the hundreds.
To count the tenths and the unit of days the operation is the same. For the tenths press the “temperature”
button and for the units the “door open” button.