Outdoor Unit
1. The outdoor unit must be installed
at a convenient site that is not
exposed to strong winds. The site
should be dry and well ventilated.
2. The site must support the weight
of the outdoor unit and allow for
vertical installation.
3. There must not be the possibility of
increased noise and vibration at
the site.
4. The unit must be installed at a site
where the noise produced by its
operation and air discharge does
not disturb the neighbors or
animals.
5. The site cannot have any leakage
of flammable gases.
6. The site must allow for a piping
extension of no less than 5 meters
(16 feet) and for pipes measuring
at least 10 meters (33 feet) in
length.
7. The site must provide enough
space around the unit, as shown in
the diagram.
8. Children must not be able to
access the installation site.
More
than 60cm
More
than 30cm
More
than 200cm
More
than 30cm
More
than 60cm
09 electrolux outdoor unit
Manual operation (without remote control)
Manual operation can be used
temporarily in case you can not find
the remote controller or its batteries
are exhausted.
1. Open and lift the front panel up to
an angle until it remains fixed with
a clicking sound.
2. One press of the manual control
button will lead to the forced
AUTO operation.
3. Close the panel firmly to its
original position.
Manual control
button
Once you push the manual button,
the operation mode is shifted in an
order as: AUTO, COLD, OFF.
Push the button twice, the unit will
operate in forced Cold mode. This is
used for testing purposes only .
Third press will stop the operation
and turn off the air conditioner
operation.
To restore the remote controller
operation, use the remote controller
directly.
Auto/Cold
manual operation (without remote control) electrolux 46