Do not put the end
of drain hose into water.
Do not block
water flow
by a rise.
Connective pipe and drainage installation
Drainage
1. Run the drain hose sloping
downward. Do not install the drain
hose as illustrated below.
2. When connecting extension drain
hose, insulate the connecting part
of extension drain hose with a
shield pipe, do not let the drain
hose slack.
Connective pipe installation
1. For the left-hand and right-hand
piping, remove the pipe cover from
the side panel.
2. For the rear-right-hand and rear-left-
hand piping, install the piping as
shown. Bend the connective pipe to
be laid at 43mm height or less from
the wall.
3. Fix the end of the connective pipe.
Right back
piping
Pipe cover
(left)
Pipe
holder
Pipe cover
(right)
Right piping
Connective
pipe
Indoor unit
outline
43mm
indoor unit installation electrolux 14
Do not block
water flow
by a rise.
1. Pass the piping through the hole in
the wall.
2. Put the upper claw at the back of the
indoor unit on the upper hook of the
installation plate, move the indoor
unit from side to side to see that it is
securely hooked (see Fig.10 &
Fig.11).
Fastening the Indoor Unit
Upper hook
Lower hook
41 electrolux how the air conditioner works
SLEEP mode
Press the sleep button to activate the
sleep mode. To deactivate, press the
button again.
Cold only mode:
• The indoor unit fan operates at a
low velocity.
• After and hour of operation, the
adjusted temperature will increase
1º C. After, the unit keeps
operating 2ºC above the adjusted
temperature.
In heating mode (some models):
• The indoor unit fan operates at a
low velocity.
• After and hour of operation, the
adjusted temperature will decrease
1º C. After, the unit keeps
operating 2º C below the adjusted
temperature.
1 °C
1 hour 1 hour
Set
temperature
SLEEP FUNCTION (Cooling mode)
1 °C
1 °C
1 hour 1 hour
SLEEP FUNCTION (Heating mode)
7 hours
1 °C
Set
temperature
Sleep function is only availaible in
the Cold/Heat and AUTO mode.