Air purging with vacuum pump
1. Check that each tube(both liquid and gas side tubes) between the indoor
and outdoor units have been properly connected and all wiring for the test
run has been completed. Remove the service valve caps from both the gas
and the liquid side on the outdoor unit. Note that both the liquid and the gas
side service valves on the outdoor unit are kept closed at this stage.
2. When relocate the unit to another place, perform evacuation using vacuum
pump.
3. Pipe length and refrigerant amount:
Caution in handling the packed valve
1. Open the valve stem until it hits against the stopper. Do not try to open it
further.
2. Securely tighten the valve stem cap with a spanner or the like. Valve stem
cap tightening torque.
electrical work electrolux 26
Air purging
metod
Less than 5 m
More than 5m
Additional amount of
refrigerant to be charged
Connective
pipe length
Use vacuum pump.
Use vacuum pump.
Half union
Refrigerant
A
C
D
B
Packed valve
Gas
Indoor unitOutdoor unit
Flare nut
Stopper
Cap
Valve stem
Valve body
Liquid side:φ6.35mm
R410a: (Pipe length-5)x20g/m
Liquid side:φ9.52mm:
R410a: (Pipe length-5)x40g/m
Operation test
Perform test operation after completing gas leak check at the flare nut
connections and electrical safety check.
1. Connect the power, press the
ON/OFF button on the remote
controller to turn the unit on.
2. Use the MODE button to select
COLD, HEAT, AUTO and FAN to
check if all the functions works
well.
3. When the ambient temperature is
too low(lower than 17ºC), the unit
cannot be controlled by the remote
controller to run at cooling mode,
manual operation can be taken.
Manual operation is used only when
the remote controller is disable or
maintenance necessary.
29 electrolux operation test
Manual control button
Auto/Cold
Manual control
button
Auto
Cold
or