13
based detergents (e.g. trichloro-ethylene) or abrasive powders
for cleaning. Coat the metal panels with vaseline oil.
The trolleys must be cleaned with high pressure water jets.
Drain off the water used in the process of cleaning by removing
the drain plug at the bottom center of the chamber, so that the
liquid flows out into the drain tray under the cabinet. This tray
must be emptied periodically (AOFP061U, AOFP101U,
AOFP102U models).
Refit the drain plug immediately after the cleaning.
Note: make sure the drain tray has been emptied before
removing the drain plug.
ATTENTION: the AOFP201RU model does not have a drain tray.
Make sure the drain hole is connected to the water drain system.
C.2.1 SWITCHING ON
Switch on the fused disconnet switch or the main circuit breaker
switch and press the I = ON button to start the appliance. The
I = ON indicator light lights up to signal that the appliance is
powered up.
C.2.2 OPERATION
C.2.2.1 Selecting a standard cycle
The default setting on the appliance is the SOFT chilling cycle.
Use these buttons
to select one of the following
options:
From left to right:
• Positive "SOFT CHILLING"
• Positive "HARD CHILLING"
• Positive "COOLER" maintenance (or preservation)
• Negative "BLAST FREEZING" chilling or freezing
• Negative "FREEZER" maintenance (or preservation)
When choosing a cycle, press the
button to move on to the
next option; the options are in a loop and so you can either scroll
forwards
or backwards .
If you want another cycle, keep pressing the
button until
the indicator light for the chosen cycle turns orange, and start it
by pressing the
button.
IMPORTANT:The appliance recognizes automatically when the
food (core) probe is inserted in to the product. If the probe hasn’t
been inserted in to the product, a timed cycle will start
automatically.
It is necessary to wait 2 minutes after the end of the preparation
cycle for the automatic recognition (see section below).
START/STOP CYCLE
This button starts or stops the selected cycle.
The selected cycle starts immediately when enabled. To stop
the cycle, keep the button pressed for at least 3 seconds.
If the door is closed when a cycle is started the button will light
up continuously. If the door is opened during a cycle it will start
blinking continuously.
1- "PREP" To optimize appliance performance when the need
arises, a preparation cycle can be chosen at the beginning of
a chilling cycle which is signalled on the temperature display
by the message “PREP”.
2- If the chiller has been inactive for a long time, the compressor
will be started by impulses to guarantee maximum efficiency.
Consequently, if a timed cycle starts, after 2 minutes the TIME
INDICATOR LIGHT will switch on and the CHAMBER TEMPERA-
TURE will be displayed by default.
C.2.2.2 Selecting a program:
First of all, the user has to decide what kind of cycle to launch
(SOFT, HARD, etc.) and then select the program.
Go through the following steps:
• Select the type of cycle;
• Press the program select button
; the program indicator
light
lights up.
• if the type of program is right, start it by pressing button .
if not
• keep pressing the select button until the chosen
program indicator light
switches on.
• to start the program, press the
button.
The user can edit some of the cycle parameters and save the
changes:
- for blast chilling, the user can edit the chamber chilling time/
setpoint and save it in the memory, from where it can
subsequently be retrieved (see section C.2.2.3 and C.2.2.4).
- for positive maintenance, the user can set the chamber
setpoint.