14
C.2.2.3 Changing the chilling time
The chilling time can be edited in two situations:
1) when setting a program (P1 o P2)
2) when selecting a chilling cycle.
THE CHILLING TIME CAN NEVER BE EDITED WHEN A CYCLE
IS RUNNING.
To change the time, proceed as follows:
• press the
button for 2 seconds;
• the display blinks to signal that you are in “edit” mode;
• set the value with either the
buttons;
• press the
button to confirm the setting, if a selection
is not made after 5 seconds, the last value displayed will be
confirmed automatically.
C.2.2.4 Changing the chamber temperature during chilling
In custom cycles only, the setpoint can be changed with the
following procedure:
• press the
button for 2 seconds;
• the display blinks to signal that you are in “edit” mode;
• set the value with the
buttons;
• press the
button to confirm the setting, if a selection
is not made after 5 seconds, the last value displayed will be
confirmed automatically.
C.2.2.5 Displaying the temperature setpoint and chilling end
time
When a cycle is running, the user can view the temperature
setpoint and chilling end time by pressing buttons and
simultaneously.
C.2.2.6 Changing the Standard selection
To select a Standard, e.g. the Electrolux Food Safe Mode 2,
press the
button, press the button until the
Standard utility is selected,
press the button to enter, press the button to select
the Standard
either press the button again to
confirm the selection or it will be confirmed automatically if
nothing is pressed for 12 seconds.
C.2.2.7 Editing USER parameters
To edit a parameter, select the utility:
• press the
button;
• the display blinks to show that the parameter is in ‘edit’ mode;
• press the
buttons to change the value within the
setting range;
• press the button to confirm the settings; if a selection is not
made after 5 seconds, the last value displayed will be confirmed
automatically, or press again.
NOTE: the parameters can be edited ONLY if no cycle is running.
If a cycle is running, the utility will enable only the display of the
parameters.
See section D.6 for the “List of user parameters”.
C.2.3 BLAST CHILLING/PRESERVATION CYCLE
When the chilling or freezing cycle has finished, the appliance
will automatically go into the preservation stage. It is important
for the chilled food to be kept in an appropriate way, maintaining
a preservation temperature suitable for the type of food chilled.
C.2.4 DEFROSTING
If the appliance is in the right conditions (indicator light
or or with the appliance on standby), this function
enables a manual defrosting cycle. The display shows the
message “dEfr” throughout the entire cycle.
If a manual defrosting is not possible (during a chilling cycle) the
message “UTIL NONE” will appear on the display.
The selection is enabled only in preservation/maintenance and
when selecting the operating cycle.
When the defrosting is finished the system will go back to the
main configuration. The cycle times and the intervals between
defrostings are preset by the manufacturer.
- Manual defrosting
To start a manual defrosting, proceed as follows:
• PRESS THE
BUTTON; THE DEFROSTING INDICATOR
LIGHT WILL TURN ORANGE, THE REST WILL STAY GREEN.
• PRESS
AGAIN TO CONFIRM.
To shorten the defrosting time, the function can be run with the
door open, or a manual defrosting can be started with the chiller
Comentarios a estos manuales