Service
Manual
Edition
Type
12. Function Sequences
12
17 9108
Page
Heating
The following conditions must be met for relay K21/valve Y51 (11) to be
energised:
The door must be closed and locked, and the programmer knob must be
in position I (see ”Power supply and start” sequence)
Row M, stop (1) must not be programmed
The out-of-balance switch must not have tripped (breaks K53:51-52 (2)
power supply)
Row K, drain (3) must not be programmed
The drum must be filled with water to the correct level.
Level control B1 (6) has two closing contacts, 21-23 (low water level)
and 31-33 (high water level). Which of these is active depends on
whether row N (5) is programmed or not.
If the above conditions are met, the closing contact in thermostat B11 (10)
is energised.
The thermostat has three different temperature settings, using the three
dials B, D and F. Which setting the thermostat is to follow depends on
whether row B (7), D (8) or F (9) has been programmed on the program
card.
If any of the three rows are programmed, and the water temperature is
lower than the set temperature, the closing contact 11-13 in the thermostat
switches and relay K21/valve V51 (11) is energised.
12