Service
Manual
9406
NOTE: Marking
on chip facing
right way
Repair Instructions
A faulty electronic unit must be replaced, not
repaired.
Removing the circuit board
• Unplug the board connectors and the tube to the
level detector (see diagram below).
• Unscrew the 6 screws that secure the board.
• Unplug the connector from the keyswitch and the
ribbon from the control panel.
Changing the memory chip for user programs
If the control board has to be replaced, the program
chip containing programs created by the user may be
moved to the new board, provided the chip is not
faulty.
Carefully remove the chip from its socket and transfer
it to the new board.
IMPORTANT
The memory chip must be installed the right
way round in accordance with the markings on
the chip and the socket.
Check that the programs in the transferred memory
chip can now be selected with the new circuit board.
Check that the programs statistics are correct (by
selecting program number 00 and pressing PROG
INFO). The statistics display must not show the
characters ?\>, only numbers.
If any of the above does not work, the original
memory supplied with the new board must be
installed and the wash programs will have to be
reprogrammed.
23
1103
1379
Programmed chip
with user programs
Example FLE 360
Hose for level control
4
23. Programmer
Comentarios a estos manuales