34. Inlet valve, water
Data
Capacity at 300 kPa 300 l/min
Operating limits 40-1000 kPa
Description
The valve is electromagnetically operated and has
a rubber diaphragm as its opening and closing
element. The valve utilises the water pressure
when opening and closing.
When the electromagnetic is de-energised, the
valve is closed.
The water pressure acts through the pilot pressure
opening on the top of the rubber diaphragm.
Because the water pressure is acting on a relatively
larger area on the top of the diaphragm than on the
bottom (part of the underside of the diaphragm is in
contact with the outlet of the valve, where there is
no pressure) the water pressure from below is
insufficient to lift the diaphragm, so that the
diaphragm forms a seal against the valve seat.
When the magnet is energised, the opening from
the top of the diaphragm to the outlet of the valve is
opened. Since the diameter of this opening is
greater that that of the pilot opening, the diameter
of which is limited by the balancing nozzle, the
pressure on the top of the diaphragm falls. The
water pressure on the bottom of the diaphragm can
then lift the diaphragm and open the valve.
Coil
Armature
Balancing
nozzle
Inlet
Valve body
Coil
Armature
Duct to valve outlet
1
34
Com-
pres-
sion
spring
Diaph-
ragm
Outlet
Compression
Spring
Pilot pressure
duct
Balancing nozzle
Rubber diaphragm