Service
Manual
9406
Data
Rated output See section 2. Data
Connections Y – connection at 380V
D – connection at 220V
Description
The three elements are situated at the bottom of
the space between the inner and outer drums. They
are actuated by a heat relay which in turn is
controlled by the programme unit and thermostat.
Repair instructions
Heating time unusually long
• Using universal instrument check if one of the
elements are burned out.
• Lime deposits can cause reduced element
performance. refer to manufacturer's instructions
for correct use of descaler. Select permanent
press 90° program.
• To access element:
– Remove lower protective plate at the front of
the machine.
– Fold up the rubber strip at the outer ends of
the stay which is fitted above the lower
protective plate and unscrew the stay.
– Unscrew the drip guard over the elements.
40. Heating
1
D – connection for 220V
Y – connection for 380V
Element
Sensor bulb
Earth
Drip-guard
Bar
40
Rubber strip